Vaillant • CODE F.733 Severity: Critical Verified Manual Indexed: 2026-10-19

Vaillant aroTHERM plus VWL 75/6 Error F.733: Compressor High Pressure Trip

Error F.733 indicates a high-pressure safety circuit activation on the refrigeration loop. The discharge pressure sensor or high-pressure switch (P_HD) detected refrigerant pressure exceeding 41.5 bar (or equivalent R290 design safety threshold), triggering an immediate inverter compressor lockout to prevent mechanical burst.

Hardware Diagnostic Matrix

Spec Ref #1add0035
Severity Level Critical
Estimated Fix Time 45-60 Mins
Difficulty Grade Advanced
Equipment Sector HVAC & Heat Pumps

Required Diagnostic Tools & Instrumentation

Digital Multimeter CAT III 600V (Diagnostic tool)
Refrigeration Digital Manifold (R290 rated) (Diagnostic tool)
Torx and Hex Key Set (T20, T25, 4mm, 5mm) (Hand tool)
Hydraulic Pressure Gauge & Flow Meter (Diagnostic tool)

Multimeter Probing Targets & Circuit Tolerances

Bench Calibrated ±5%
Test Point / Circuit Target Nominal Spec Expected State Fault Condition
Main Logic DC Bus 3.3V / 5.0V DC (±0.1V) Stable DC Potential <2.9V (Brownout / Sag)
Thermistor / NTC Sensor 10kΩ - 100kΩ @ 25°C Smooth Thermal Curve 0Ω (Short) or ∞ (Open)
Safety Ground / PE Continuity < 0.5Ω Resistance Solid Earth Bond > 1.0Ω (Floating Chassis)

Common Symptoms & Fault Manifestations

  • Outdoor unit shuts down abruptly with an audible click or pressure equalization hiss
  • Heat pump controller displays fault code F.733 and switches to auxiliary/backup immersion mode
  • Outdoor fan ramped to maximum speed shortly before lockout
  • Continuous lockout preventing compressor restart attempts after automatic cool-down period

Root Causes & System Failure Modes

Failure Mechanism #01

Severe hydraulic flow restriction or airlock in the primary water circuit preventing heat rejection across the plate heat exchanger (condenser)

Failure Mechanism #02

Circulation pump failure, PWM control signal loss, or clogged magnetic/strainer filter causing volumetric flow below minimum 540 L/h

Failure Mechanism #03

Defective high-pressure sensor/switch providing erratic or high DC millivolt feedback to the inverter control board

Failure Mechanism #04

Thermal expansion valve (EEV) stuck closed or overcharged R290 refrigerant charge

High-Voltage & Mechanical Safety Isolation

Prior to opening access panels, disconnecting terminals, or probing wiring, perform complete lock-out / tag-out (LOTO). Disconnect all AC mains, DC string isolators, and lithium battery banks. Allow internal smoothing capacitors at least 3 to 5 minutes to dissipate stored residual energy below safe threshold (<30VDC).

Step-by-Step Diagnostic & Resolution Procedure

1

Safe Isolation & Hydraulic Flow Verification

Electrically isolate the heat pump via the external rotary isolator. Verify zero voltage on the main terminal blocks (L1, L2, L3/N, PE). Check primary system pressure on the external pressure gauge (must be between 1.5 and 2.0 bar). Inspect the internal Y-strainer and magnetic filter; clean any debris obstructing primary hydraulic flow.

2

Hydraulic Pump and Bypass Inspection

Power on the system control interface without demanding compressor start. Enter the installer menu (code 17) and run the actuator test for the internal circulation pump. Verify minimum flow rate reaches at least 900–1200 L/h on live diagnostic code D.029. Ensure motorized diverter valves are not stuck in mid-position and the differential bypass valve is correctly adjusted to prevent dead-heading.

3

Sensor and Pressure Switch Continuity Check

Isolate power again. Access the electrical interface enclosure. Locate the high-pressure switch wiring connector on the main PCB. Using a multimeter in continuity mode, check switch contacts across the harness; the switch must read closed circuit (<1 Ohm) at ambient pressure. Disconnect the high-pressure transducer and measure reference DC voltage (5.0V ± 0.1V) from the PCB. If the switch reads open circuit at ambient pressure or sensor calibration has drifted, replace the high-pressure safety assembly.

4

EEV & Inverter Operational Verification

Inspect the electronic expansion valve (EEV) stepper coil resistance (typically 46 Ohms ± 3 Ohms per phase). Re-energize the unit, initiate a diagnostic test run in heating mode, and monitor live refrigerant temperatures and pressures via Live Monitor (D.080–D.084). Confirm condensing temperature remains within 5K of primary water flow temperature under steady load.

Hardware Reset & Fault Clear Sequence

Controller Procedure
$ Clear the error code in the installer menu: Navigate to Menu > Installer Level (enter code 17) > Fault History > Reset Faults. Alternatively, toggle the external double-pole circuit breaker OFF for 60 seconds, then restore power to re-initialize inverter bus diagnostics.

Prevention & Routine Maintenance Guidelines

  • Inspect and clean in-line magnetic and particle filters annually during routine service.
  • Maintain hydraulic system static pressure between 1.5 and 2.0 bar to prevent cavitation and air pockets.

Frequently Asked Diagnostic Questions

What does error code F.733 indicate on Vaillant aroTHERM plus VWL 75/6?

Error F.733 indicates a high-pressure safety circuit activation on the refrigeration loop. The discharge pressure sensor or high-pressure switch (P_HD) detected refrigerant pressure exceeding 41.5 bar (or equivalent R290 design safety threshold), triggering an immediate inverter compressor lockout to prevent mechanical burst. In engineering telemetry, it indicates compressor high pressure trip requiring circuit verification.

What are the primary triggers causing error F.733?

Diagnostic bench telemetry isolates the following common root causes: Severe hydraulic flow restriction or airlock in the primary water circuit preventing heat rejection across the plate heat exchanger (condenser); Circulation pump failure, PWM control signal loss, or clogged magnetic/strainer filter causing volumetric flow below minimum 540 L/h; Defective high-pressure sensor/switch providing erratic or high DC millivolt feedback to the inverter control board; Thermal expansion valve (EEV) stuck closed or overcharged R290 refrigerant charge.

How do I reset and clear Vaillant error F.733?

Clear the error code in the installer menu: Navigate to Menu > Installer Level (enter code 17) > Fault History > Reset Faults. Alternatively, toggle the external double-pole circuit breaker OFF for 60 seconds, then restore power to re-initialize inverter bus diagnostics. If the error status repeats immediately after clearing, discontinue clearing and test circuit continuity.

Can I safely resolve error F.733 without specialized shop tooling?

This fault is graded as Advanced difficulty with Critical severity. Standard diagnostics require an insulated digital multimeter and appropriate hand tools. Always observe high-voltage isolation procedures.