1 Documented Faults • Full Multimeter & Safety Isolation Procedures

Indexed Fault Codes for aroTHERM plus VWL 75/6 A

Step-by-step resolution manuals and root cause matrices

1 Codes
CODE F.733 Severity: Critical Difficulty: Advanced

Compressor High Pressure Trip

Error F.733 indicates a high-pressure safety circuit activation on the refrigeration loop. The discharge pressure sensor or high-pressure switch (P_HD) detected refrigerant pressure exceeding 41.5 bar (or equivalent R290 design safety threshold), triggering an immediate inverter compressor lockout to prevent mechanical burst.

⏱ 45-60 Mins Troubleshoot Now →