Hardware Engineering Diagnostic Index & Bench-Tested Field Manuals
Equipment Sector Directory

Portable Power Stations & LiFePO4 Energy Troubleshooting

Pure sine wave inverter overload trips, high-voltage MPPT solar controller faults, BMS temperature protection codes, and battery pack recalibration.

8 Supported Manufacturers • 119 Documented Error Codes

Indexed Fault Guides in Power Stations

Machine-verified error code diagnostic walkthroughs

119 Guides
Anker • CODE E03 SOLIX F3800 High

Inverter DC Bus Overvoltage

Error E03 triggers when the internal bidirectional inverter's high-voltage DC intermediate bus exceeds its safe operational voltage threshold (typically over 420V-450V DC). The Power Management System (PMS) locks out AC output and charging circuitry to prevent catastrophic failure of the primary IGBTs and bus capacitors.

⏱ 20-30 Mins View Guide →
Anker • CODE E04 SOLIX F3800 High

Inverter DC Bus Overvoltage Trip

Error E04 triggers when the bi-directional inverter internal DC bus voltage exceeds safe hardware thresholds (typically >420V-450V DC). This occurs primarily during aggressive regenerative backfeed from inductive loads, solar PV open-circuit spikes, or rapid grid voltage fluctuations during AC pass-through.

⏱ 30-45 Mins View Guide →
Anker • CODE E06 SOLIX F3800 High

High Solar Input Voltage Overload

Error E06 triggers when the DC input voltage to the MPPT charge controller exceeds the maximum absolute rating (60V DC on the low-voltage XT60 port or 140V DC on the high-voltage XT-60 port), causing the internal hardware over-voltage protection (OVP) circuit to trip and isolate solar charging to prevent MOSFET breakdown.

⏱ 20-30 Mins View Guide →
Bluetti • CODE E088 AC200L Portable Power Station High

High PV Input Voltage Lockout

Error code E088 triggers when the open-circuit voltage (Voc) applied to the DC/PV input exceeds the hardware protection threshold of the internal MPPT controller (rated maximum 145V DC). The firmware initiates an immediate charge lockout to prevent catastrophic MOSFET breakdown.

⏱ 15-20 Mins View Guide →
Bluetti • CODE E011 AC240 High

PV Input Overvoltage Shutdown

The Bluetti AC240 hardware protection triggered Error E011 due to open-circuit voltage (Voc) at the DC/PV input exceeding the maximum rated threshold of 60V DC. The internal MPPT step-down controller has isolated the PV input bus via protective MOSFET switching to prevent gate breakdown and capacitor failure.

⏱ 15-20 Mins View Guide →
Bluetti • CODE E088 AC200L High

MPPT Over-Voltage Lockout Fix

Error code E088 indicates that the DC input voltage to the internal MPPT controller has exceeded the maximum rated safe threshold (145VDC), triggering a hardware-level safety shutdown to prevent buck converter MOSFET breakdown.

⏱ 15-30 Mins View Guide →
Bluetti • CODE E034 AC240 IP65 Water Resistant Power Station Critical

Inverter AC Short Circuit Protection

Error E034 triggers when the DSP controller detects an overcurrent spike or dead short across the pure sine wave inverter H-bridge output terminals, locking out the AC bus to protect the MOSFETs.

⏱ 20-30 Mins View Guide →
Anker • CODE E06 SOLIX F3800 High

AC Inverter Overload Short Circuit

Error E06 indicates that the high-voltage AC pure sine wave inverter hardware protection circuit detected an instantaneous overcurrent, short circuit, or continuous load exceeding the 6,000W split-phase threshold, prompting a safety gate shutdown.

⏱ 20-30 Mins View Guide →
Bluetti • CODE E049 AC200L High

MPPT Solar Over-Voltage Protection Trip

The internal MPPT charge controller detected open-circuit voltage (Voc) exceeding the maximum hardware safety threshold of 145V DC on the DC/PV input port, triggering hardware protection to prevent catastrophic damage to the buck-boost conversion circuitry.

⏱ 15-30 Mins View Guide →
Anker • CODE E32 SOLIX F3800 High

AC Inverter Overload Cutoff

Error code E32 indicates the bidirectional AC inverter sustained an instantaneous current or sustained wattage draw exceeding safety thresholds (typically >6000W surge or sustained >3840W continuous output), triggering software hardware protection to isolate the H-bridge MOSFETs.

⏱ 20-30 Mins View Guide →
Bluetti • CODE E034 AC200L High

Solar MPPT Input Overvoltage

Error E034 indicates the internal MPPT charge controller detected incoming DC voltage from the solar/PV array exceeding the maximum hardware safety threshold of 145V DC, triggering automatic hardware shutdown to protect the front-end MOSFETs.

⏱ 15-30 Mins View Guide →
Bluetti • CODE E041 AC200L Critical

PV Input Overvoltage Trip

Error E041 indicates that the DC/PV input voltage exceeded the maximum open-circuit limit of 145VDC, triggering the internal MPPT hardware overvoltage protection and latching the input relay to protect the DC-DC buck stage.

⏱ 20-30 Mins View Guide →
Zendure • CODE F08 SuperBase V4600 High

MPPT Controller PV Input Lockout

The internal MPPT charge controller has engaged a hardware lock state (F08) due to over-voltage, reverse polarity, excessive inrush current, or a short circuit detected at the XT90/Anderson solar input ports.

⏱ 20-30 Mins View Guide →
Anker • CODE E041 SOLIX F3800 Critical

AC Output Short Circuit Overload

Error E041 indicates that the inverter microprocessor detected an immediate AC output short-circuit condition, an instantaneous peak current overload exceeding hardware thresholds (such as 6000W surge limit), or backfed AC voltage on the NEMA 14-50 or L14-30 output ports.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE Error 086 DELTA Pro 3 High

High Voltage MPPT Overvoltage Trip

Error 086 triggers when the high-voltage solar MPPT input port registers an open-circuit voltage (Voc) or transient surge exceeding the maximum rating (typically 150V DC or 600V DC depending on high-voltage port architecture), prompting the BMS and charge controller to trip overvoltage protection to prevent semiconductor destruction.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 301 DELTA Pro 3 High

AC Pass-Through Overload Protection

Error 301 triggers when the bidirectional inverter detects an aggregate load on the AC output ports exceeding the safe pass-through rating (typically >3600W/30A at 120V or thermal limit under continuous bypass), forcing the AC transfer relay to trip to protect the internal bus and switching MOSFETs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE PHASE-LOCK-ERR DELTA Pro 3 Critical

Split-Phase Inverter Phase Lock Fault

The internal bi-directional dual-inverter failed to synchronize the phase angle between L1 and L2 to exactly 180 degrees, or failed phase-locking loop (PLL) synchronization with an incoming AC grid/generator reference in split-phase mode. Hardware protection trips the AC output relays to prevent destructive shoot-through and circulating current.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR 115 DELTA Pro 3 High

High-Voltage Solar BMS Communication Fault

Error code ERR 115 signifies a communication timeout or data packet corruption between the internal High-Voltage Solar Input Controller (MPPT DC-DC subsystem) and the master Battery Management System (BMS). When the high-voltage bus (up to 150V DC / 15A) engages, the system isolates the charging circuitry via internal relay disengagement to protect the LiFePO4 battery pack from unregulated power flow.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 112 DELTA Pro 3 Critical

Dual Inverter Sync Bypass Trip

Error 112 indicates that the internal dual-inverter synchronization circuit detected a phase discrepancy or high-voltage transient on the AC bypass bus, triggering hardware crowbar protection and locking out output relays to protect the split-phase power stage.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE E021 DELTA Pro Ultra High

HV Solar MPPT Overcurrent Protection

Error E021 triggers when the high-voltage (HV) MPPT charge controller detects an input current exceeding its hardware rating (15A continuous, with transient limits). The internal DC-DC converter latches into hardware protection to safeguard the inverter's input bridge and switching MOSFETs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR 301 DELTA Pro 3 Critical

Solar PV High Voltage Overload

Error code ERR 301 trips when the open-circuit voltage (Voc) applied to the High-Voltage Solar Input port exceeds the hardware threshold (typically 150V DC on the HV port or 60V DC on LV inputs), triggering an emergency BMS lock and disabling the MPPT controller to prevent MOSFET dielectric breakdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR302 DELTA Pro 3 High

Bi-Directional Inverter Overload DC Bus

The ERR302 code indicates that the internal power management unit detected an overcurrent or overvoltage condition on the high-voltage DC bus linking the battery management system (BMS) and the bi-directional inverter bridge, triggering immediate hardware protection shutdown.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE Error 101 DELTA Pro 3 High

High-Voltage MPPT Overcurrent

Error 101 indicates the DELTA Pro 3's high-voltage solar MPPT tracker detected DC input current exceeding the maximum safe threshold (rated limit typically 15A), tripping the hardware or software overcurrent protection (OCP) circuit to prevent MPPT buck-boost MOSFET thermal breakdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 102 DELTA Pro 3 High

Split Phase Inverter Overload Fault

Error 102 indicates an active split-phase bi-directional inverter overload or phase-balance fault. The internal DSP detected that current on either L1 (120V) or L2 (120V) exceeded rated limits, or an excessive phase-to-phase current imbalance occurred while operating in 120V/240V split-phase dual-voltage mode.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 302 DELTA Pro 3 Critical

Bidirectional Inverter Split-Phase Overload

Error 302 indicates an instantaneous hardware overcurrent or sustained thermal overload on the bidirectional inverter stage during 120V/240V split-phase operation, tripping software-level protection or hardware fast-acting current sensors.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 303 DELTA Pro 3 High

High Voltage Solar BMS Comm Error

Error 303 indicates an internal CAN/UART communication timeout or protocol mismatch between the high-voltage solar MPPT charge controller subsystem (30-150V port) and the main Battery Management System (BMS). This failsafe disengages the DC input relays to protect internal cell blocks.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE Overload 302 DELTA Pro 3 Critical

Bi-Directional Inverter Pure Sine Wave Lockup

Error Code 302 designates a hardware-level overcurrent or short-circuit protection trip in the bi-directional inverter module. The system has latched the AC full-bridge H-bridge MOSFETs into high-impedance mode to prevent thermal runaway or DC-bus collapse caused by extreme inrush current, back-fed AC phase mismatch, or bridge driver latch-up.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR_066 DELTA Pro 3 High

High Voltage PV Overvoltage Fault

Error code ERR_066 is triggered when the DELTA Pro 3's high-voltage PV port detects an input open-circuit voltage (Voc) exceeding the 150V DC threshold, or when internal serial communication between the dedicated high-voltage MPPT sub-controller and the main BMS/logic board fails under high electrical stress.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR036 DELTA Pro 3 High

PV Overvoltage Protection Tripped

Error ERR036 triggers when the open-circuit voltage (Voc) applied to the High Voltage Solar Input port exceeds the internal MPPT controller's absolute maximum rating of 150V DC. The safety hardware disconnects the solar charging bus to protect internal MOSFETs and DC-link capacitors from dielectric breakdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 304 DELTA Pro 3 High

Solar Charging Overvoltage Cut-Off

Error 304 triggers when the PV input exceeds the maximum open-circuit voltage (Voc) threshold (typically 150V DC on the high-voltage port or 60V DC on the low-voltage port), forcing the MPPT controller into protection shutdown to prevent MOSFET dielectric breakdown.

⏱ 15-30 Mins View Guide →
EcoFlow • CODE D025 DELTA Pro Ultra Critical

High Voltage Battery Communication Fault

Error code D025 indicates a breakdown in isolated CAN bus serial communication between the DELTA Pro Ultra Inverter Module and the High Voltage (HV) LFP Battery Pack BMS. The inverter master controller triggers a fail-safe shutdown to prevent unmonitored charging or discharging across the high-voltage DC bus.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE 088 DELTA Pro Ultra Critical

HV Battery Communication Timeout

Error 088 trips when the inverter head unit fails to establish or maintain bidirectional CAN/RS-485 communication with the internal BMS of one or more connected high-voltage (102.4V nominal) LFP battery packs within a 3000ms heartbeat window.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 303 DELTA Pro Ultra High

High-Voltage PV Inverter Overload

Error 303 indicates that the DELTA Pro Ultra's High-Voltage (HV) Solar/PV MPPT inverter stage has exceeded its maximum rated power (5600W), voltage (450V DC), or peak current input. The protection circuitry disengages solar charging to protect the internal DC-DC converter and switching FETs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE F007 DELTA Pro Ultra Critical

High Voltage MPPT Bus Overvoltage

Error code F007 indicates a hardware-level safety lockout on the high-voltage solar MPPT input. The internal DC bus detected open-circuit or operational voltage exceeding the rated 450VDC threshold, triggering gate drive shutdown to prevent catastrophic MOSFET/IGBT breakdown.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE E041 DELTA Pro 3 High

Dual Solar MPPT Overcurrent Trip

Error E041 indicates a dual solar MPPT hardware overcurrent protection trip. The internal DC-DC charge controller detected input current exceeding absolute hardware limits (High-PV port >30A peak or Low-PV port >15A peak), triggering an immediate solid-state disconnect to protect the buck-boost MOSFETs.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE E15 DELTA Pro 3 High

High Voltage Solar Overload

Error E15 triggers when the high-voltage photovoltaic (PV) input port detects open-circuit voltage (Voc) or sustained operating voltage exceeding the maximum threshold of 150V DC (or maximum wattage limits), initiating hardware protection to prevent MPPT charge controller damage.

⏱ 15-30 Mins View Guide →
EcoFlow • CODE ERR303 DELTA Pro 3 High

Solar Input Overvoltage Protection Trip

Error ERR303 indicates that the MPPT solar charge controller has triggered hardware overvoltage protection (OVP). Open-circuit voltage (Voc) exceeding the maximum rating (e.g., 60V on the low-voltage PV port or 150V on the high-voltage PV port) was detected at the input terminals, shutting down charging to prevent MOSFET breakdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 062 DELTA Pro 3 Critical

BMS Overload Relay Lockout

Error 062 indicates a safety lockout triggered by the Battery Management System (BMS) due to sustained AC/DC inverter overload or inrush current, causing the main DC contactor/relay to latch open or weld shut to prevent thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR-303 DELTA Pro 3 Critical

DC Bus Pre-Charge Failure

During power-on initialization, the bi-directional inverter's pre-charge circuit failed to bring the high-voltage DC link capacitor bank to the target threshold (approx. >380V DC) within the mandated pre-charge window (typically <500ms), triggering protective lockout ERR-303 to prevent destructive inrush current on the primary bypass contactor/FETs.

⏱ 45-60 Mins View Guide →
EcoFlow • CODE ERR-BMS-302 DELTA Pro 3 High

Cell Overvoltage Imbalance Error

Error ERR-BMS-302 trips when the internal Battery Management System detects an individual LiFePO4 cell exceeding the maximum safe threshold (typically >= 3.65V) or an inter-cell delta exceeding 150mV during high-voltage/high-current PV charging, triggering a charge cutoff latch to prevent thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE CAN-BMS-DROP DELTA Pro Ultra Critical

CAN Bus Battery Pack Drop

The inverter controller detected excessive packet frame drops or frame transmission timeouts across the high-speed differential CAN 2.0B bus linked to the master battery pack BMS. In response, safety relays open, disconnecting the battery bank to prevent uncontrolled charge/discharge states or thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE BMS-053 DELTA Pro Ultra Critical

HV Bus Precharge Failure

The Battery Management System (BMS) detected that the DC high-voltage bus failed to achieve the target threshold (>90% of nominal battery voltage, approx. 92V-102V DC) within the specified precharge window (typically <500ms) prior to main contactor closure, preventing catastrophic inrush current.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE Err106 DELTA Pro Ultra Critical

HV Battery Comms Failure

Err106 designates a communication loss or packet timeout across the internal high-voltage CAN bus link between the DELTA Pro Ultra Inverter Module and the connected LFP Battery Pack(s). When BMS heartbeat telemetry drops below threshold, the inverter trips isolation relays to mitigate thermal and electrical hazards.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR301 DELTA Pro Ultra Critical

HV DC Bus Comm Fault

Error ERR301 indicates a critical communication timeout or packet corruption over the internal CAN/UART link between the High-Voltage (HV) DC-to-DC boost controller and the primary inverter DSP board, causing the system to isolate the 300V-450V DC bus for safety.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 043 DELTA Pro Ultra Critical

HV Inverter Short Circuit Trip

Error Code 043 indicates that the DELTA Pro Ultra's High Voltage (HV) split-phase inverter output stage detected an overcurrent/short circuit condition on the 120V/240V AC output rails. The digital signal processor (DSP) immediately shut down PWM gating to protect the power MOSFET/IGBT bridge from catastrophic thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 302 DELTA Pro Ultra Critical

BMS Inverter Communication Lost

Error 302 signifies a complete loss of CAN/RS485 data telemetry between the DELTA Pro Ultra inverter module and the stacked high-voltage LFP battery pack BMS. As a safety interlock, the inverter shuts down AC/DC outputs and halts HV DC bus charging to prevent over-voltage or thermal runaway.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR_114 DELTA Pro 3 Critical

High Voltage MPPT Overvoltage

Error ERR_114 indicates that the internal High-Voltage MPPT charge controller detected incoming DC solar input voltage exceeding the absolute maximum limit of 150V DC (rated 30-150V DC, 15A max). The firmware triggered emergency hardware isolation to prevent catastrophic destruction of the buck-boost MOSFETs and primary DC link capacitor bank.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE BMS-301 DELTA Pro Ultra Critical

BMS High Voltage Disconnect

Fault BMS-301 occurs when the DELTA Pro Ultra inverter loses high-voltage DC bus synchronization or differential CAN bus communication with an expansion battery pack, triggering safety isolation contactors to prevent HV arcing or thermal events.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR_BMS_028 DELTA Pro Ultra Critical

HV Battery Interlock Communication Fault

ERR_BMS_028 indicates an open or unstable High-Voltage Interlock Loop (HVIL) or broken CAN bus communication circuit between the DELTA Pro Ultra inverter head and the external high-voltage LFP battery pack. The system has automatically isolated the DC bus contactors to prevent arcing and thermal events.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 089 DELTA Pro Ultra Critical

Inverter Output MOSFET Thermal Trip

Error Code 089 indicates an over-temperature protection trip on the high-voltage split-phase inverter stage. The primary power MOSFET/IGBT heatsink thermistor detected temperatures exceeding safety thresholds (>105°C), forcing an immediate inverter shutdown to prevent silicon junction breakdown.

⏱ 45-60 Mins View Guide →
EcoFlow • CODE Error 138 DELTA Pro Ultra Critical

BMS Communication Timeout Fault

Error 138 indicates a high-priority CAN/RS-485 serial communication handshake failure between the central inverter control board and the internal battery management system (BMS) pack or downstream modular battery units, triggering immediate AC/DC shutdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE HV-BATT-COMM-CUTOFF DELTA Pro Ultra Critical

High Voltage Battery Communication Cutoff

The DELTA Pro Ultra Inverter detected an interruption or packet degradation on the proprietary CAN bus linking to the high-voltage LFP battery module. To prevent uncontrolled high-voltage DC transfer, the main contactors opened, triggering an emergency high-voltage isolation fault.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE AC-OVERLOAD-DVL DELTA Pro 3 High

Dual Voltage AC Overload Trip

The bi-directional inverter's protection circuit triggered continuous tripping due to an excessive load surge, neutral-ground bonding loop, or split-phase imbalance exceeding the 4000W continuous / 8000W surge threshold across the 120V/240V split-phase bus.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 028 DELTA Pro 3 Critical

HV PV Relay Latch Failure

Error 028 indicates a relay latch or pre-charge circuit failure on the High Voltage Photovoltaic (HV PV) MPPT boost stage. The main controller detected that the input isolation relay failed to cycle, welded shut, or could not overcome pre-charge bus differential voltage.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 095 DELTA Pro 3 Critical

BMS Communication Link Failure

Error 095 indicates a loss of CAN bus/RS485 data telemetry between the internal/external Battery Management System (BMS) and the Master Control Board (MCB). When communication packets drop or timeout exceeding preset thresholds, the MCB trips protection interlocks, disabling AC/DC charge and discharge to prevent cell imbalance or thermal runaway.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE 043 DELTA Pro 3 High

Inverter High Ambient Overload

Error 043 triggers when the primary or secondary high-voltage inverter stage exceeds safe junction thermal limits under load due to excessive ambient operating temperatures (>45°C) or restricted forced-air cooling paths. The internal power management system locks out AC output to protect IGBT/MOSFET switches and DC-link bus capacitors from catastrophic thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 403 DELTA Pro 3 High

Bi-Directional Inverter Surge Overload Trip

Error Code 403 indicates an AC bi-directional inverter overload trip triggered by a peak surge demand exceeding the hardware's 8000W surge threshold or a sustained inductive load exceeding 4000W continuous output. The integrated hardware protection circuit shuts down the H-bridge MOSFETs to prevent thermal avalanche.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 033 DELTA Pro Ultra Critical

High Voltage Inverter Cut Out

Error 033 triggers when the high-voltage DC bus or solar MPPT inverter stage exceeds safe operating thresholds (>450V DC), or detects an open/shorted IGBT bridge. The unit's firmware cuts output to protect the power electronics and battery bank.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 102 DELTA Pro Ultra Medium

HV MPPT High Temp Derating

Error 102 triggers when the high-voltage MPPT (Solar Port 2, 80-450V DC) heatsink or booster MOSFET temperature exceeds safe operating thresholds (>85°C). The BMS and inverter controller enforce thermal derating or charge cutoff to protect internal power electronics.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE Error 304 DELTA Pro Ultra Critical

Inverter DC HV Bus Comm Failure

Error 304 triggers when the main system controller loses UART/CAN telemetry from the bidirectional inverter's high-voltage DC bus monitoring circuit. The BMS immediately disables AC/DC output paths to prevent uncontrolled DC link voltage runaway or IGBT shoot-through.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE Fault 301 DELTA Pro Ultra Critical

High-Voltage PV Isolation Fault

Fault 301 indicates that the High-Voltage (HV) Solar/PV input has detected either open-circuit voltage exceeding the 450V DC hardware ceiling or an active insulation resistance breakdown (isolation fault) to chassis ground while under high potential.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE Error 003 DELTA Pro 3 High

Inverter Inductive Surge Overload

Error 003 indicates that the bidirectional inverter H-bridge detected an instantaneous current spike exceeding the hardware peak current threshold (overcurrent/desaturation protection). This typically occurs when starting high inrush inductive loads (e.g., heavy compressors, AC units, well pumps) or from transient back-EMF feedback.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 106 DELTA Pro 3 High

AC Output Overload Error 106

Error 106 indicates an AC inverter hardware overcurrent protection event caused by severe inrush current exceeding surge limits (typically >8000W transient or prolonged >4000W continuous) from highly inductive loads like compressors, pumps, or large power tools.

⏱ 15-20 Mins View Guide →
EcoFlow • CODE 087 DELTA Pro 3 High

MPPT High Voltage PV Overcurrent

Error code 087 indicates that the high-voltage MPPT solar charge controller has detected an incoming direct current (DC) amperage exceeding its maximum rated hardware threshold (nominal continuous limit is 15A; peak trip threshold at approximately 16.5A-17A). The charge controller automatically isolates the PV input to protect the internal buck-boost circuitry and power MOSFETs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE HV-PV-OVP-BMS-TRIP DELTA Pro 3 Critical

High Voltage Solar Overload Trip

The EcoFlow DELTA Pro 3 high-voltage PV charging port exceeded its operational limit (max 150V DC / 15A), causing the Battery Management System (BMS) and internal MPPT controller to latch into hardware overvoltage and overcurrent protection to prevent busbar damage and battery cell degradation.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR305 Delta Pro 3 High

High-Voltage PV Input Overvoltage

Error ERR305 triggers when the open-circuit voltage (Voc) applied to the Delta Pro 3 high-voltage PV port exceeds the maximum allowable hardware threshold of 150V DC. The internal MPPT controller opens protection MOSFETs to prevent overvoltage breakdown of input filter capacitors and switching semiconductors.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 104 DELTA Pro 3 High

AC Inverter Inductive Overload 104

Error 104 triggers when the AC inverter's hardware current-sensing circuitry (shunt/hall sensor) detects an inrush current exceeding the unit's peak surge threshold (typically >8000W peak or >70A momentary spike), caused by high inductive loads such as heavy compressors, pumps, or large electric motors tripping the fast overcurrent protection (OCP).

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 032 DELTA Pro Ultra Critical

High Voltage PV Overvoltage Fault

The internal High-Voltage MPPT controller detected an open-circuit voltage (Voc) exceeding the absolute maximum threshold of 450V DC on the High-PV port, triggering safety isolation relays to prevent inverter MOSFET breakdown.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 049 DELTA Pro Ultra Critical

Inverter HV Bus Overvoltage

Error 049 is triggered when the internal DC high-voltage bus linking the DC-DC boost stage and the DC-AC full-bridge inverter exceeds safety thresholds (>450V DC). The firmware latches the gate drivers into a shutdown state to prevent catastrophic IGBT/MOSFET rupture.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 062 DELTA Pro Ultra High

Battery Communication Link Lost

Error 062 indicates a CAN bus/RS485 serial communication failure between the DELTA Pro Ultra inverter module and the expansion LFP battery pack. The inverter safety supervisor tripped due to missing heartbeat telemetry packets.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 045 DELTA Pro 3 High

Solar Input BMS Communication Failure

Error 045 indicates an internal communication timeout or packet corruption between the High-Voltage Solar Input Controller/MPPT subsystem and the primary Battery Management System (BMS). The system trips input protection relays to prevent over-voltage battery charging.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 059 DELTA Pro 3 High

Battery Discharge Overcurrent Trip

Error 059 triggers when the internal Battery Management System (BMS) detects DC discharge current exceeding safe hardware thresholds (typically >105A peak surge or continuous rated limit), immediately shutting down inverter and DC output rails to protect the LiFePO4 cells and low-side MOSFET bank.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 101 DELTA Pro 3 High

AC Inverter High Voltage Cutoff

Error 101 triggers when the bidirectional inverter's internal DSP detects an incoming AC grid or generator voltage surge exceeding the safety threshold (typically >140VAC on 120V nominal lines or >265VAC on 230V nominal systems), causing the pass-through relay and inverter circuit to immediately latch off to prevent downstream board and connected appliance damage.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE Error 303 DELTA Pro 3 High

Inverter Overload Low Load Trip

Error 303 signals that the inverter protection circuit tripped due to an anomalous current surge or DC bus imbalance detected during low-load or no-load conditions. The primary AC output safety relay disengages to prevent shoot-through failure in the GaN/MOSFET H-bridge stage.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE PHASE-SYNC-FAIL DELTA Pro 3 Critical

240V Split-Phase Sync Failure

The bidirectional high-frequency inverter's Phase-Locked Loop (PLL) failed to synchronize L1 and L2 legs within the required 180-degree (+/- 5 degrees) phase offset, causing the master DSP to trip protection relays to prevent cross-phase short circuits or reverse backfeed.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR 106 DELTA Pro 3 High

Dual Inverter Phase Sync Overload

Dual-inverter phase synchronization and overcurrent protection tripped on the L1/L2 split-phase topology. The internal digital signal processors (DSPs) detected an excessive phase-angle deviation from 180 degrees, circulating neutral currents, or severe dynamic cross-conduction between the two 120V inverter bridges under load.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE BAT_DISCHARGE_OCP DELTA Pro Ultra Critical

Battery Discharge Overcurrent Trip

The inverter controller detected an instantaneous or sustained discharge current exceeding safe hardware limits across the high-voltage DC bus (102.4V nominal LiFePO4 stack), prompting a hardware-level safety shutdown to prevent cell degradation, FET thermal runaway, or inverter bridge failure.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR 120 DELTA Pro Ultra Critical

Inverter Communication Bus Failure

Error ERR 120 denotes a CAN/RS-485 bus communication timeout or data packet corruption between the main battery management system (BMS)/system controller and the internal bidirectional high-voltage AC inverter module. The system has entered a hardware failsafe state to prevent out-of-sync switching and DC bus runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 094 DELTA Pro Ultra Critical

HV Battery Communication Loss

Error 094 indicates a fatal CAN bus/RS485 communication timeout between the DELTA Pro Ultra Inverter Module and the external High Voltage LFP Battery Pack (nominal 102.4V). The master BMS safety interlock trips, preventing inverter engagement and battery discharge to prevent unmonitored cell imbalance or thermal events.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 301 DELTA Pro Ultra Critical

Inverter HV DC Bus Overcurrent

Error 301 triggers when the high-voltage DC bus (nominally 380V-420V DC) linking the battery boost stage and the bidirectional inverter detects an instantaneous current spike exceeding safe operational thresholds (typically >35A peak). The DSP controller trips hardware shutdown to protect the primary power MOSFETs/IGBTs from punch-through failure.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE INV 301 DELTA Pro Ultra Critical

INV 301 HV Bus Overvoltage

Error code INV 301 indicates that the internal DC High-Voltage (HV) bus has exceeded the safety overvoltage threshold (typically nominal 380V-420V DC spiking past 450V DC). The inverter protection circuit triggers an immediate hardware latch-off to protect power MOSFETs/IGBTs from breakdown caused by PV overvoltage spikes, regenerative back-EMF, or AC input surges.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR-304 DELTA Pro 3 Critical

High-Voltage Solar Overvoltage Lockout

Error ERR-304 triggers when open-circuit voltage (Voc) on the high-voltage PV port exceeds the hardware threshold of 150V DC (often exacerbated by low temperature coefficients), causing the MPPT controller to latch shut to protect internal DC bus capacitors and buck-boost MOSFETs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR_BMS_301 DELTA Pro 3 High

Cell Overvoltage Imbalance Fault

Error ERR_BMS_301 triggers when the Battery Management System detects an individual LiFePO4 cell voltage exceeding the upper safety threshold (>= 3.65V to 3.75V) or an excessive inter-cell delta (> 100mV-150mV) during charging, disabling input charge FETs to prevent thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 306 DELTA Pro 3 High

High Voltage Solar Overcurrent Fault

Error 306 indicates that the high-voltage MPPT solar charge controller or Battery Management System (BMS) detected DC input current exceeding the design limit (15A continuous, with hardware trip typically occurring near 16A-17A). The charge controller has entered hardware protection mode to protect internal MOSFETs and the main LiFePO4 battery bus.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE HV-BYPASS-TRIP DELTA Pro 3 High

Bidirectional Inverter Bypass Tripping

The EcoFlow DELTA Pro 3's high-voltage bidirectional inverter bypass mechanism trips when the transfer relay encounters excessive inrush current, grid phase-angle mismatch, or internal DC-link overvoltage during AC grid-to-battery passthrough transition.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR_123 DELTA Pro 3 Critical

DC-DC Inverter Overcurrent Fault

The main bidirectional inverter controller tripped hardware overcurrent protection on the primary DC-DC intermediate stage. This occurs when instantaneous current through the primary H-bridge or synchronous rectifiers exceeds factory safety thresholds during high-power charging or discharge transitions.

⏱ 45-60 Mins View Guide →
EcoFlow • CODE BMS-014 DELTA Pro Ultra Critical

High Voltage Solar MPPT Overvoltage

Fault code BMS-014 indicates the internal High-Voltage (HV) MPPT charge controller detected open-circuit string voltage (Voc) exceeding the safety ceiling of 450V DC (hardware absolute max 500V DC). The solid-state protection switches tripped to prevent catastrophic destruction of the internal buck-boost stage and battery bus.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE BMS 302 DELTA Pro Ultra Critical

BMS High Voltage Communication Loss

Error code BMS 302 on the EcoFlow DELTA Pro Ultra indicates an internal or inter-stack CAN/RS485 communication timeout between the high-voltage battery management system (BMS) and the inverter unit, triggering a protective relay disconnect to prevent unbalanced HV DC bus operation.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE BMS-OVP-LOCK DELTA Pro Ultra Critical

BMS Cell Overvoltage Lock

The Battery Management System (BMS) detected a single or multi-cell LFP voltage spike exceeding the hard ceiling threshold (typically >=3.75V per cell or total pack safety ceiling), triggering a latching protection lock to isolate the DC high-voltage bus and halt charge/discharge operations.

⏱ 45-60 Mins View Guide →
EcoFlow • CODE BMS_ERR_017 Delta Pro Ultra High

HV Discharge Communication Timeout

Error BMS_ERR_017 indicates a loss of CAN bus or serial heartbeat telemetry between the Delta Pro Ultra battery pack BMS and the inverter module during high-voltage (>100V DC) discharge operation, triggering automated protective contactor isolation.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE Err024 DELTA Pro Ultra High

High Voltage PV Overload Cutoff

Err024 triggers when the High-Voltage (HV) Solar Input port exceeds maximum allowable DC input limits (rated 450V DC Max, 15A Max). The internal MPPT controller opens input protection FETs to prevent bus overvoltage and inverter damage.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE Error 102 DELTA Pro Ultra Critical

BMS Communication Link Failure

Error 102 indicates an interruption or packet loss in the high-voltage serial/CAN bus communication between the inverter unit and the external LFP battery module. The main controller initiates safe shutdown of high-voltage DC contactors to prevent thermal runaway or unbalanced pack discharge.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE HV-BMS-COMM-TIMEOUT DELTA Pro Ultra High

HV Solar BMS Communication Timeout

The inverter unit has lost real-time CAN bus telemetry from the internal charge controller or stack battery BMS during high-voltage solar harvesting (80-450V DC). The central supervisory controller trips solar charging protection to prevent thermal runaway and overvoltage.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE E031 DELTA Pro 3 High

High-Voltage MPPT Overcurrent Lock

Error E031 triggers when the high-voltage solar MPPT input controller detects an incoming current exceeding the maximum design limit (typically >15A continuous or a transient inrush spike over threshold), causing the firmware to latch an overcurrent protection lock on the photovoltaic subsystem.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE ERR_062 DELTA Pro 3 Critical

Bidirectional Inverter Overcurrent Fault

Hardware protection triggered by the bidirectional inverter stage detecting instantaneous current exceeding safe operational limits (>40A peak AC bus or rapid DC link surge) during high-load charging or sudden AC surge discharge.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 103 DELTA Pro 3 High

Inverter Overload Inrush Shutoff

Error 103 trips when the bidirectional inverter detects an instantaneous peak current draw exceeding the surge capacity rating (typically >8000W peak or sustained >4000W at 120V/240V), initiating immediate solid-state protection to prevent MOSFET and H-bridge destruction.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 305 DELTA Pro 3 High

AC Inverter Overload Protection Lock

Error 305 indicates that the internal bidirectional AC inverter has engaged a hard software lock due to continuous sustained over-current, an extreme surge demand exceeding peak limits (over 8000W surge or 4000W continuous), or a dead short circuit detected on the AC output bus.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE INV-OVLD-HV-CUTOFF DELTA Pro 3 High

Inverter Overload High Voltage Cutoff

The bi-directional inverter detected an AC over-voltage condition or regenerative inductive back-EMF spike that exceeded the DC bus operating ceiling (>450V DC), triggering the hardware Over-Voltage Protection (OVP) cut-off to protect the GaN/MOSFET H-bridge.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE INV-OVLD-PV-OVP DELTA Pro 3 High

Inverter Overload PV Fault

The bi-directional inverter control MCU tripped protection due to simultaneous AC inverter load saturation and an over-voltage condition on the high-voltage solar (PV) input port exceeding the 150V DC threshold.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE OVERLOAD-4000W-TRIP DELTA Pro 3 High

DELTA Pro 3 False Overload Trip

The unit triggers a false continuous AC overload protection trip at or below its rated 4000W threshold. This fault typically originates from uncalibrated current shunt sensors, high inrush current triggers on purely resistive or reactive loads, out-of-spec power factor tolerance, or outdated inverter DSP firmware thresholds.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE BMS Cell Imbalance Cut-Off DELTA Pro Ultra High

BMS Cell Imbalance Cut-Off

The internal Battery Management System (BMS) tripped an over-voltage or differential cutoff due to an excessive voltage spread (>100mV–300mV) between series-connected LiFePO4 cells during high-state-of-charge operation, locking charge acceptance to prevent thermal runaway.

⏱ 30-60 Mins View Guide →
EcoFlow • CODE 038 DELTA Pro Ultra Critical

High Voltage PV Overvoltage Trip

Error 038 indicates that the open-circuit voltage (Voc) applied to the High-Voltage (HV) PV input port exceeded the internal hardware limit of 450V DC. The internal MPPT charge controller initiated an emergency hardware overvoltage trip to protect the DC-DC boost stage and inverter circuitry.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 059 DELTA Pro Ultra High

BMS Battery Cell Imbalance

Error 059 triggers when the Battery Management System (BMS) detects a cell voltage delta exceeding factory threshold limits (typically >150mV–300mV variance between series LFP cells) in the high-voltage battery stack, disabling charging or discharge to prevent thermal runaway and cell degradation.

⏱ 30-60 Mins View Guide →
EcoFlow • CODE ERR03 DELTA Pro Ultra Critical

High-Voltage MPPT Overvoltage Trip

The High-Voltage (HV) MPPT input has tripped protection code ERR03 due to DC bus overvoltage exceeding the inverter's absolute maximum rating of 450V DC. In sub-freezing ambient temperatures, solar photovoltaic (PV) open-circuit voltage (Voc) increases significantly due to negative temperature coefficients, pushing series string voltage past safe operating limits.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE BMS_ERR_026 DELTA Pro Ultra Critical

HV Stack Communication Fault

The inverter central supervisor lost CAN bus packet telemetry from one or more stacked high-voltage battery modules (nominally ~102.4V per pack, up to 300V+ stacked). Safety interlocking opened internal solid-state and DC contactors to prevent DC bus desynchronization.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR_032 DELTA Pro Ultra Critical

Inverter DC Bus Overvoltage

Error ERR_032 indicates that the internal DC-DC booster has exceeded the safe maximum DC high-voltage bus threshold (nominally >450VDC) feeding the primary full-bridge inverter stage. The system initiates an emergency hardware interrupt to protect the power MOSFETs/IGBTs and filter capacitors from catastrophic dielectric breakdown.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE 030 DELTA Pro Ultra High

HV PV Soft Start Failure

Error 030 triggers when the high-voltage (HV) PV input stage fails to complete its precharge sequence. The DELTA Pro Ultra utilizes an active inrush current limiting circuit (resistors/NTCs and bypass relays) to charge internal DC-link intermediate capacitors before engaging the full MPPT boost stage. If intermediate bus voltage fails to reach the design threshold within the precharge timeout window, or an overcurrent/short circuit is sensed, the firmware trips error 030 to protect the HV inverter semiconductors.

⏱ 25-40 Mins View Guide →
EcoFlow • CODE 086 DELTA Pro Ultra High

Inverter High-Voltage MPPT Comms Failure

Error 086 indicates an internal CAN/UART communication loss between the main inverter control board and the integrated High-Voltage (HV) MPPT charge controller sub-assembly. This trips hardware protection and halts high-voltage solar harvesting.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 114 DELTA Pro Ultra High

High Voltage MPPT Bus Communication Failure

Error 114 indicates an internal communication timeout or signal integrity loss over the internal CAN/UART data bus between the High-Voltage (HV) Solar MPPT charge controller sub-assembly and the main inverter control DSP. The system locks out HV solar charging (80-450V input) to prevent uncontrolled DC bus overvoltage or catastrophic thermal runaway.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR 022 DELTA Pro Ultra Critical

Inverter Soft Start Precharge Failure

Error ERR 022 triggers when the high-voltage DC bus precharge circuit fails to elevate the DC-link capacitor voltage to the target threshold (typically >90% of nominal ~102V battery pack voltage) within the designated soft-start timeout window, aborting full inverter contactor engagement to prevent inrush current damage.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR 027 DELTA Pro Ultra Critical

Stack Communication Bus Timeout

The main inverter management unit failed to establish or maintain bidirectional CAN/RS-485 serial communication with the high-voltage LFP battery stack BMS over the proprietary inter-stack connection bus. This trips system-wide safety cutoffs and halts power conversion.

⏱ 30-45 Mins View Guide →
EcoFlow • CODE ERR_084 DELTA Pro Ultra Critical

Battery Inverter CAN Bus Fault

Error ERR_084 indicates a loss of internal CAN/RS485 data telemetry between the DELTA Pro Ultra Inverter Module and the stackable LFP Battery Pack. The system BMS isolates DC contactors to prevent unmonitored thermal or overcurrent states.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE ERR_INV_301 DELTA Pro Ultra Critical

Split Phase Inverter Overcurrent

Error ERR_INV_301 indicates hardware protection trip caused by an instantaneous or sustained overcurrent condition across the 120V/240V split-phase inverter bridge. The inverter's primary current shunt or Hall sensor detected current exceeding peak threshold (typically >30A continuous or >60A surge per leg), tripping gate drivers to protect the silicon carbide (SiC) MOSFET array.

⏱ 30-45 Mins View Guide →
Anker • CODE E01 SOLIX F3800 Plus High

AC Inverter Overload Lockout

Error E01 triggers when the bidirectional inverter detects an AC output current or wattage spike exceeding continuous (6,000W) or peak surge (9,000W) thresholds, an active downstream dead short, or a neutral-ground bonding phase conflict via an external transfer switch.

⏱ 20-30 Mins View Guide →
Anker • CODE E04 SOLIX F3800 Plus High

AC Output Overload Trip

Error Code E04 indicates that the internal digital signal processor (DSP) detected an AC output overcurrent or excessive surge demand exceeding continuous (6,000W) or peak (9,000W for >200ms) inverter thresholds, or encountered a severe phase imbalance across the split-phase L1/L2 120V/240V legs.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE OVERLOAD-AC EcoFlow Delta Pro 3 High

AC Output Overload Trip / Inverter Protection Locked

The Delta Pro 3 4000W high-frequency pure sine wave inverter shuts down all 120V and 240V AC output sockets with an audible alarm and pulsing OVERLOAD indicator when an inductive appliance inrush current exceeds the 8000W X-Boost surge threshold.

⏱ 10 Mins View Guide →
EcoFlow • CODE ERR 032 DELTA Pro Ultra High

Inverter Bus Overvoltage Surge

Error ERR 032 triggers when the internal high-voltage DC bus exceeds safe operating thresholds (typically >450V DC) during dynamic or reactive load switching. Inductive loads like well pumps, air compressors, or heavy motor drivers produce back-EMF and transient voltage spikes that feed back into the DC intermediate circuit, causing the DSP supervisory controller to trip protective latching isolation to prevent bridge MOSFET/IGBT breakdown.

⏱ 20-35 Mins View Guide →
EcoFlow • CODE 048 DELTA Pro Ultra High

Inverter BMS Communication Loss

Error 048 indicates a serial data bus failure between the DELTA Pro Ultra inverter module and the Battery Management System (BMS) over the internal RS-485 interface. The inverter controller trips into fail-safe mode and cuts off AC/DC output when telemetry heartbeat frames are interrupted.

⏱ 20-30 Mins View Guide →
EcoFlow • CODE 103 DELTA Pro Ultra High

BMS Cell Imbalance Cutoff

BMS Error 103 triggers when the internal battery management system detects an excessive cell voltage variance (Delta V typically exceeding 150mV to 250mV) across the 16S LiFePO4 series pack during active charging or heavy discharge. The BMS executes a balance cutoff to prevent individual cell overvoltage (>3.65V) or deep discharge collapse (<2.50V).

⏱ 45-60 Mins View Guide →