CODE E3 Air 10 Pro High

Sapphire Cooling Sensor Cut-Off

Error E3 indicates an open-circuit, short-circuit, or anomalous temperature reading detected across the NTC thermistor embedded in the sapphire contact cooling head. To prevent thermal epidermal burns or Peltier cell failure, firmware halts pulse generation.

⏱ 25-35 Mins Troubleshoot →
CODE E2 Air 10 IPL Hair Removal Device High

Sapphire Cooling Thermal Sensor Trip

Error code E2 indicates an open-circuit, short-circuit, or over-temperature condition at the negative temperature coefficient (NTC) thermistor monitoring the sapphire ice-cooling contact head and Peltier thermoelectric cooler (TEC). The MCU halts flash discharge and cooling drive to prevent epidermic thermal injury.

⏱ 20-30 Mins Troubleshoot →
CODE Flashing Blue Indicator with Continuous Beeping Air 3 IPL Hair Removal Device High

Blue Flash Continuous Beeping Fault

The Ulike Air 3 indicates a flash inhibit fault state through rapid blue LED blinking and continuous acoustic buzzer warnings. This lockup is triggered by the MCU detecting open-loop Peltier/sapphire thermistor feedback, high flash-head temperature, skin-contact capacitive/optical sensor occlusion, or under-voltage on the main xenon discharge capacitor rail.

⏱ 20-30 Mins Troubleshoot →
CODE E2 Air 10 Pro Critical

Xenon Capacitor Charging Timeout

The main microcontroller triggered an E2 safety lockout due to the dual-lamp high-voltage photoflash capacitor failing to reach target operational potential (typically 380V-420V DC) within the maximum allowed charging window (exceeding 1200ms).

⏱ 30-45 Mins Troubleshoot →
CODE E2 Air 3 IPL Hair Removal Handset High

Sapphire Cooling Overheat Shutdown

The E2 fault triggers when the internal NTC thermistor detects an over-temperature state exceeding 55°C at the thermoelectric peltier assembly or sapphire contact window, forcing an emergency shutdown to prevent thermal skin burns and protect the Xenon flash tube.

⏱ 20-35 Mins Troubleshoot →
CODE Alternating Blue and White Light Air 3 IPL Hair Removal Device High

Sapphire Ice-Cooling Subsystem Failure

The alternating blue and white flashing LED sequence signals a thermal management fault in the Peltier thermoelectric cooling (TEC) circuit or internal NTC thermistor loop. The MCU trips hardware interlocks to prevent epidermal burns from a non-chilled sapphire window or component degradation from an uncooled xenon flash lamp.

⏱ 20-30 Mins Troubleshoot →