Indexed Error Codes for Growatt

Machine-verified error code diagnostic walkthroughs

7 Manuals
CODE Error 201 MIN 5000TL-XH High

Transient Leakage Current Fault

Error 201 indicates the internal Residual Current Monitoring Unit (RCMU) detected an excessive transient leakage current (residual current spike typically >30mA or sudden jump >30mA to ground) exceeding safety limits defined in DIN VDE 0126-1-1 / IEC 62109-2, causing the inverter to immediately disconnect from the grid.

⏱ 30-45 Mins Troubleshoot →
CODE Error 102 MIN 5000TL-X Critical

Internal DSP Sampling Inconsistency Fault

Error 102 indicates a hardware sampling inconsistency between the master and slave Digital Signal Processors (DSP) or redundant analog-to-digital converter (ADC) channels. The safety supervisor detected a divergence in internal voltage/current telemetry across the internal bus, tripping redundant safety shutdown relays.

⏱ 30-45 Mins Troubleshoot →
CODE Error 407 MIN 5000TL-XH High

Auto Test PV Isolation Low

Error 407 triggers when the inverter's internal diagnostic test detects that the insulation resistance between the DC PV array conductors and earth is below the safety threshold (typically <50 kΩ or standard local limit), preventing grid synchronization to avoid electrical shock or ground-fault fires.

⏱ 30-45 Mins Troubleshoot →
CODE 04 SPF Series (SPF 3000TL / SPF 5000ES) High

Inverter Soft Start Failure

Fault 04 trips when the inverter's DC-to-AC conversion stage fails to ramp up the AC output voltage to target operating parameters (230VAC) within the designated soft-start window. This safety mechanism protects the power conversion board from destructive overcurrent events typically caused by high inrush loads connected during startup, an external AC short circuit, or failed internal H-bridge power switches.

⏱ 30-45 Mins Troubleshoot →
CODE 08 SPF 5000 ES Critical

Bus Voltage Too High

Error Code 08 represents an internal DC bus over-voltage condition (exceeding 500VDC internally). This is a critical protective shutdown to protect the main capacitor bank and IGBT bridge from catastrophic rupture.

⏱ 30-45 Mins Troubleshoot →
CODE 02 SPF 5000 ES Medium

Heatsink Over Temperature

Error Code 02 triggers when internal thermal sensors register temperatures exceeding 90°C (194°F) on the main power MOSFET heatsink or transformer core.

⏱ 20-30 Mins Troubleshoot →
CODE 04 SPF 5000 ES High

Low Battery Voltage

Error Code 04 indicates that the battery bank voltage has plummeted below the low-voltage cutoff threshold configured in the inverter settings, prompting an emergency shutdown to prevent irreversible battery cell degradation.

⏱ 15-25 Mins Troubleshoot →