CODE E103
Severity: High
Difficulty: Intermediate
RTK Satellite Positioning Signal Timeout
Error E103 triggers when the Navimow EFLS 2.0 (Exact Fusion Locating System) fails to achieve or sustain a centimeter-level RTK (Real-Time Kinematic) GNSS fix within the internal timeout threshold (typically 60-120 seconds). The controller enters a safety hold, halting drive motors and cutting power to the cutting disc.