Indexed Fault Codes for AC200L
Step-by-step resolution manuals and root cause matrices
High PV Input Voltage Lockout
Error code E088 triggers when the open-circuit voltage (Voc) applied to the DC/PV input exceeds the hardware protection threshold of the internal MPPT controller (rated maximum 145V DC). The firmware initiates an immediate charge lockout to prevent catastrophic MOSFET breakdown.
MPPT Solar Over-Voltage Protection Trip
The internal MPPT charge controller detected open-circuit voltage (Voc) exceeding the maximum hardware safety threshold of 145V DC on the DC/PV input port, triggering hardware protection to prevent catastrophic damage to the buck-boost conversion circuitry.
Solar MPPT Input Overvoltage
Error E034 indicates the internal MPPT charge controller detected incoming DC voltage from the solar/PV array exceeding the maximum hardware safety threshold of 145V DC, triggering automatic hardware shutdown to protect the front-end MOSFETs.
PV Input Overvoltage Trip
Error E041 indicates that the DC/PV input voltage exceeded the maximum open-circuit limit of 145VDC, triggering the internal MPPT hardware overvoltage protection and latching the input relay to protect the DC-DC buck stage.