Indexed Fault Codes for SOLIX F3800 Plus
Step-by-step resolution manuals and root cause matrices
AC Inverter Overload Lockout
Error E01 triggers when the bidirectional inverter detects an AC output current or wattage spike exceeding continuous (6,000W) or peak surge (9,000W) thresholds, an active downstream dead short, or a neutral-ground bonding phase conflict via an external transfer switch.
AC Output Overload Trip
Error Code E04 indicates that the internal digital signal processor (DSP) detected an AC output overcurrent or excessive surge demand exceeding continuous (6,000W) or peak (9,000W for >200ms) inverter thresholds, or encountered a severe phase imbalance across the split-phase L1/L2 120V/240V legs.