Viessmann Diagnostics & Fault Manuals

Premium Vitodens gas boilers and Vitocal heat pump solutions.

Support: Viessmann Technical Helpdesk • Official OEM Portal

Indexed Error Codes for Viessmann

Machine-verified error code diagnostic walkthroughs

5 Manuals
CODE F.1034 Vitocal 250-A Critical

EEV Stepper Motor Desync Fault

Error F.1034 indicates that the electronic expansion valve (EEV) stepper motor has lost step synchronization during initialization or active superheat modulation. The refrigeration controller detects inconsistent coil phase feedback or failed end-stop calibration, locking out the compressor to prevent liquid refrigerant floodback.

⏱ 45-60 Mins Troubleshoot →
CODE F.1039 Vitocal 250-A Critical

EEV Low Pressure Refrigerant Fault

Error F.1039 trips when the Vitocal 250-A refrigeration controller detects an abnormal suction pressure drop caused by a malfunctioning electronic expansion valve (EEV), stepper motor failure, wiring fault, or severe refrigerant loss, triggering compressor safety shutdown.

⏱ 45-90 Mins Troubleshoot →
CODE F.1044 Vitocal 250-A Critical

High Pressure Switch Open

Safety fault F.1044 triggers when the electromechanical high-pressure switch (PSH) in the R290/R410A refrigerant circuit trips and opens the safety chain, usually exceeding approximately 28 to 31 bar due to poor secondary heat dissipation, air locks, pump failure, or overcharging.

⏱ 45-75 Mins Troubleshoot →
CODE 07 Vitocal 250-A High

EEV Stepper Motor Fault

Error 07 indicates that the refrigeration circuit controller detected a synchronization loss, open/short circuit, or mechanical seizure in the electronic expansion valve (EEV) stepper actuator during positioning cycles, locking out compressor operation to prevent liquid floodback.

⏱ 30-60 Mins Troubleshoot →
CODE F.1074 Vitocal 250-A High

Minimum Volume Flow Deficit

The heat pump controller detected that the secondary heating circuit volume flow rate fell below the critical threshold required for safe evaporator heat exchange or defrost cycles, triggering a safety shutdown to prevent plate heat exchanger freeze-up.

⏱ 30-45 Mins Troubleshoot →