1 Documented Faults • Full Multimeter & Safety Isolation Procedures

Indexed Fault Codes for Altherma 3 R32 Split/Monobloc Series

Step-by-step resolution manuals and root cause matrices

1 Codes
CODE L5 Severity: Critical Difficulty: Advanced

Inverter Instantaneous Overcurrent Fault

Error L5 indicates the outdoor inverter PCB detected instantaneous hardware overcurrent across the compressor drive circuit (IPM). This protection trips when current draw exceeds safe thresholds, caused by compressor winding failure, mechanical seizure, or shorted IGBT switches.