CODE Code 1610008E Severity: Medium Difficulty: easy

IMU Calibration Required (Code 1610008E)

DJI Goggles 3 HUD displays critical warning: 'Aircraft IMU abnormal. Recalibrate IMU (Code 1610008E)'. The CineWhoop cannot acquire flight readiness, attitude horizon line in OSD spins or tilts, and motor start is locked out.

CODE 30064 Severity: Critical Difficulty: Advanced

ESC Status Abnormal Fault

Error 30064 indicates the flight controller lost valid bidirectional telemetry or detected an abnormal electrical state across the integrated 4-in-1 Electronic Speed Controller (ESC). This occurs when the ESC microcontroller detects a blown half-bridge MOSFET, an open/shorted motor phase winding, or overcurrent/phase desynchronization during pre-flight self-test.