Hardware Engineering Diagnostic Index & Bench-Tested Field Manuals
NVIDIA • CODE XID 119 Severity: Critical Verified Manual Indexed: 2026-10-23

NVIDIA HGX H200 8-GPU Board Error XID 119: GSP-RM RPC Timeout Failure

An XID 119 event indicates an RPC communication failure between the host kernel driver and the GPU System Processor (GSP) firmware on one or more Hopper SXM5 modules, leading to NVLink interconnect desynchronization, NVSwitch fabric stalls, and dropped NCCL collective communication rings.

Hardware Diagnostic Matrix

Spec Ref #2af54330
Severity Level Critical
Estimated Fix Time 45-90 Mins
Difficulty Grade Advanced
Equipment Sector AI Accelerators & HPC Hardware

Required Diagnostic Tools & Instrumentation

NVIDIA Field Diagnostic (NVFD / nvvs) Suite (Diagnostic tool)
Torque Screwdriver with T10/T15 Torx Bits (Calibrated to 1.2 Nm) (Hand tool)
Calibrated ESD Grounding Wrist Strap & Mat (Safety gear)
Baseboard Management Controller (BMC) Out-of-band Console (Diagnostic tool)

Multimeter Probing Targets & Circuit Tolerances

Bench Calibrated ±5%
Test Point / Circuit Target Nominal Spec Expected State Fault Condition
Main Logic DC Bus 3.3V / 5.0V DC (±0.1V) Stable DC Potential <2.9V (Brownout / Sag)
Thermistor / NTC Sensor 10kΩ - 100kΩ @ 25°C Smooth Thermal Curve 0Ω (Short) or ∞ (Open)
Safety Ground / PE Continuity < 0.5Ω Resistance Solid Earth Bond > 1.0Ω (Floating Chassis)

Common Symptoms & Fault Manifestations

  • Kernel log reports 'NVRM: Xid (PCI:0000:xx:00): 119, pid=xxxx, RPC to GSP timed out'
  • Distributed multi-GPU training jobs crash instantly with 'NCCL WARN Call to connect returned Connection refused / Network failure'
  • nvidia-smi hangs indefinitely in D-state or reports GPUs in 'ERR!' / 'Unresponsive' state

Root Causes & System Failure Modes

Failure Mechanism #01

GSP RISC-V firmware execution hang or internal deadlock triggered by memory parity error in high-bandwidth memory (HBM3e)

Failure Mechanism #02

SXM5 connector pin degradation or localized 12V-to-0.8V VDD core VRM transient undervoltage trip under heavy NVSwitch line-rate traffic

Failure Mechanism #03

PCIe Gen5 link degradation causing uncorrectable replay timer timeouts (TLP timeouts) between CPU root complex, PCIe switch, and SXM5 baseboard

Failure Mechanism #04

NVSwitch fabric ASIC firmware desynchronization or thermals exceeding 85°C throttle limit

High-Voltage & Mechanical Safety Isolation

Prior to opening access panels, disconnecting terminals, or probing wiring, perform complete lock-out / tag-out (LOTO). Disconnect all AC mains, DC string isolators, and lithium battery banks. Allow internal smoothing capacitors at least 3 to 5 minutes to dissipate stored residual energy below safe threshold (<30VDC).

Step-by-Step Diagnostic & Resolution Procedure

1

Diagnostic Triage & Log Isolation

Capture 'nvidia-bug-report.sh' and query BMC SEL logs for SXM5 power supply fault asserts (PE_HOT, THERM_ALERT). Inspect 'dmesg -T' to identify the specific PCI BDF triggering the GSP RPC timeout.

2

Subsystem Power Cycle & Fabric Reset

A standard warm reboot fails to reinitialize the GSP. Execute an AC power cycle or complete chassis-level chassis cold boot via BMC IPMI/Redfish (`ipmitool chassis power cycle`) to cold-reset GSP-RM, SXM5 module regulators, and NVSwitch ASICs.

3

Firmware & Fabric Manager Alignment

Verify driver parity with the NVIDIA Fabric Manager daemon (`nvsm`, `nvidia-fabricmanager`). Ensure H200 driver version matches exactly with the firmware payload on SXM5 baseboard (minimum driver branch 535.161.08 / 550.54.15 or newer with GSP timeout hardening).

4

Physical Interconnect & Cold Re-seat

If XID 119 repeats consistently on the same BDF address, disconnect chassis AC mains, pull the tray, unseat the offending SXM5 module, inspect high-density mezzanine multi-pin arrays for bent/carbonized contacts, and re-torque to 1.2 Nm in an alternating X-pattern.

5

NCCL & Fabric Health Verification

Run NVIDIA System Management (`nvsm dump health`), execute Level 4 NVVS diagnostics (`nvsm test --level 4`), and run an all-reduce NCCL benchmark (`nccl-tests/build/all_reduce_perf -b 8M -e 8G -f 2 -g 8`) to verify 900 GB/s inter-GPU line-rate stability without RPC drops.

Hardware Reset & Fault Clear Sequence

Controller Procedure
$ Perform a complete out-of-band cold chassis restart: 'ipmitool chassis power cycle', wait 90 seconds for baseboard power sequencer to complete, restart nvidia-fabricmanager via 'systemctl restart nvidia-fabricmanager', and verify all 8 GPUs appear clean via 'nvidia-smi -q -d PERFORMANCE'.

Prevention & Routine Maintenance Guidelines

  • Lock Driver and Fabric Manager versions via pinned repository packages to prevent mismatched user-space and kernel RPC APIs.
  • Maintain delta-T chassis inlet temperatures below 25°C to avoid localized NVSwitch core hot-spots and transient power supply ripple.

Frequently Asked Diagnostic Questions

What does error code XID 119 indicate on NVIDIA HGX H200 8-GPU Board?

An XID 119 event indicates an RPC communication failure between the host kernel driver and the GPU System Processor (GSP) firmware on one or more Hopper SXM5 modules, leading to NVLink interconnect desynchronization, NVSwitch fabric stalls, and dropped NCCL collective communication rings. In engineering telemetry, it indicates gsp-rm rpc timeout failure requiring circuit verification.

What are the primary triggers causing error XID 119?

Diagnostic bench telemetry isolates the following common root causes: GSP RISC-V firmware execution hang or internal deadlock triggered by memory parity error in high-bandwidth memory (HBM3e); SXM5 connector pin degradation or localized 12V-to-0.8V VDD core VRM transient undervoltage trip under heavy NVSwitch line-rate traffic; PCIe Gen5 link degradation causing uncorrectable replay timer timeouts (TLP timeouts) between CPU root complex, PCIe switch, and SXM5 baseboard; NVSwitch fabric ASIC firmware desynchronization or thermals exceeding 85°C throttle limit.

How do I reset and clear NVIDIA error XID 119?

Perform a complete out-of-band cold chassis restart: 'ipmitool chassis power cycle', wait 90 seconds for baseboard power sequencer to complete, restart nvidia-fabricmanager via 'systemctl restart nvidia-fabricmanager', and verify all 8 GPUs appear clean via 'nvidia-smi -q -d PERFORMANCE'. If the error status repeats immediately after clearing, discontinue clearing and test circuit continuity.

Can I safely resolve error XID 119 without specialized shop tooling?

This fault is graded as Advanced difficulty with Critical severity. Standard diagnostics require an insulated digital multimeter and appropriate hand tools. Always observe high-voltage isolation procedures.