Hardware Engineering Diagnostic Index & Bench-Tested Field Manuals
Prusa Research • CODE 13201 Severity: High Verified Manual Indexed: 2026-10-20

Prusa Research Original Prusa MK4S Error 13201: Loadcell Tare Out of Range

During the pre-homing/mesh-bed leveling sequence, the strain gauge loadcell failed the auto-zero (tare) offset baseline verification. The analogue voltage output or raw ADC counts measured by the LoveBoard exceeded allowable tolerance margins, preventing safe bed probing.

Hardware Diagnostic Matrix

Spec Ref #5fc2fbcf
Severity Level High
Estimated Fix Time 20-30 Mins
Difficulty Grade Intermediate
Equipment Sector 3D Printers

Required Diagnostic Tools & Instrumentation

2.5mm and 1.5mm Allen Keys (Hand tool)
Digital Multimeter CAT II/III (Diagnostic tool)
Inspection Mirror or Magnifier (Inspection tool)

Multimeter Probing Targets & Circuit Tolerances

Bench Calibrated ±5%
Test Point / Circuit Target Nominal Spec Expected State Fault Condition
Main Logic DC Bus 3.3V / 5.0V DC (±0.1V) Stable DC Potential <2.9V (Brownout / Sag)
Thermistor / NTC Sensor 10kΩ - 100kΩ @ 25°C Smooth Thermal Curve 0Ω (Short) or ∞ (Open)
Safety Ground / PE Continuity < 0.5Ω Resistance Solid Earth Bond > 1.0Ω (Floating Chassis)

Common Symptoms & Fault Manifestations

  • Printer halts immediately before or during the homing sequence on Z-axis
  • LCD displays 'Error 13201: Loadcell homing tap tare out of range'
  • Toolhead taps the bed without triggering retraction or fails pre-touch tare verification
  • Loadcell diagnostic values fluctuate erratically or stay stuck at full-scale deflection

Root Causes & System Failure Modes

Failure Mechanism #01

Excessive mechanical pre-load caused by over-tightened Nextruder thumbscrews, hotend heatsink mounting screws, or bent loadcell plate

Failure Mechanism #02

Loose, misaligned, or damaged 6-pin LoveBoard-to-loadcell ribbon connector or damaged strain gauge wiring

Failure Mechanism #03

External mechanical drag from a stiff or misrouted extruder cable bundle pulling on the LoveBoard and loadcell housing

Failure Mechanism #04

Defective Nextruder loadcell assembly or failing ADC circuitry on the LoveBoard (out-of-range baseline offset > ±500g raw equivalent)

High-Voltage & Mechanical Safety Isolation

Prior to opening access panels, disconnecting terminals, or probing wiring, perform complete lock-out / tag-out (LOTO). Disconnect all AC mains, DC string isolators, and lithium battery banks. Allow internal smoothing capacitors at least 3 to 5 minutes to dissipate stored residual energy below safe threshold (<30VDC).

Step-by-Step Diagnostic & Resolution Procedure

1

Safe Isolation & Mechanical De-Tensioning

Power off the MK4S and disconnect the AC power inlet. Allow the hotend to cool to room temperature (<40°C). Inspect the extruder cable harness to ensure the textile sleeve is not pulling taut against the LoveBoard assembly, as lateral tension directly introduces baseline loadcell drift.

2

Inspect LoveBoard Connection and Cable Seating

Remove the LoveBoard cover on the rear of the Nextruder. Inspect the 4-pin/6-pin loadcell flat flexible cable (FFC) or micro-JST harness for micro-fractures, debris, or partial unseating. Disconnect, inspect pins for corrosion or bent tabs, and firmly reseat the connector square into its socket.

3

Adjust Heatsink Clamping and Torque Specifications

Loosen the two M3 screws clamping the hotend heatsink to the loadcell plate. Ensure the Nextruder idler tension screws are properly adjusted (flush with the plastic body). Retorque the heatsink clamping screws evenly to finger-tight (approx. 0.3-0.4 Nm); do not overtighten, as mechanical over-constraint warps the strain gauge substrate and causes tare saturation.

4

Run Loadcell Diagnostic Test & Calibration

Power on the MK4S. Navigate to Control > Calibration & Diagnostics > Loadcell Test. Monitor the raw value reading; lightly tap the nozzle with your finger to verify live response and confirm the reading returns to zero baseline (±15g margin). Initiate a full Z-calibration and Mesh Bed Leveling routine to ensure error 13201 is cleared.

Hardware Reset & Fault Clear Sequence

Controller Procedure
$ Clear the error prompt by pressing the rotary knob, then navigate to Menu > Control > Reset. If the fault persists upon reboot, initiate a Factory Reset (Settings > System > Factory Reset > Calibrations Only) to flush corrupt loadcell tare tables, then execute the full initial setup wizard.

Prevention & Routine Maintenance Guidelines

  • Ensure hotend nozzle swaps are performed with proper counter-torque to avoid twisting the loadcell plate
  • Do not zip-tie external wiring directly to the Nextruder heatsink or loadcell beam
  • Verify idler tension springs are not over-compressed beyond the recommended flush alignment

Frequently Asked Diagnostic Questions

What does error code 13201 indicate on Prusa Research Original Prusa MK4S?

During the pre-homing/mesh-bed leveling sequence, the strain gauge loadcell failed the auto-zero (tare) offset baseline verification. The analogue voltage output or raw ADC counts measured by the LoveBoard exceeded allowable tolerance margins, preventing safe bed probing. In engineering telemetry, it indicates loadcell tare out of range requiring circuit verification.

What are the primary triggers causing error 13201?

Diagnostic bench telemetry isolates the following common root causes: Excessive mechanical pre-load caused by over-tightened Nextruder thumbscrews, hotend heatsink mounting screws, or bent loadcell plate; Loose, misaligned, or damaged 6-pin LoveBoard-to-loadcell ribbon connector or damaged strain gauge wiring; External mechanical drag from a stiff or misrouted extruder cable bundle pulling on the LoveBoard and loadcell housing; Defective Nextruder loadcell assembly or failing ADC circuitry on the LoveBoard (out-of-range baseline offset > ±500g raw equivalent).

How do I reset and clear Prusa Research error 13201?

Clear the error prompt by pressing the rotary knob, then navigate to Menu > Control > Reset. If the fault persists upon reboot, initiate a Factory Reset (Settings > System > Factory Reset > Calibrations Only) to flush corrupt loadcell tare tables, then execute the full initial setup wizard. If the error status repeats immediately after clearing, discontinue clearing and test circuit continuity.

Can I safely resolve error 13201 without specialized shop tooling?

This fault is graded as Intermediate difficulty with High severity. Standard diagnostics require an insulated digital multimeter and appropriate hand tools. Always observe high-voltage isolation procedures.